China Indoor Handle Electromagnetic Lock Open When Electricty, Closed When No Power power lock dead space

Product Description

Product Description

This product is a kind of electric interlock device, can prevent electric misoperation of high voltage switch equipment. Mainly used for human operation indoor isolating switch, is adapted to realize it with electric interlocking between circuit break and other safety interlock need to implement compulsory interlock, prevent misoperation, is indispensable to power generation and power supply department for locking device. 

 

Specification:

1. Ambient temperature: at -25ºC to +40ºC , the special areas not less than -30ºC
2. Altitude: <1000m
3. Atmospheric condition: the daily average of relative humidity is less than 95%, the average monthly is less than 90%; the daily average of water vapor pressure is less than 2.2kPa, the average monthly is less than 1.8kPa.
4. Working environment: no dirty, no flammable and explosive chemical corrosive deposition, no salt fog.

Detailed Photos

 

Product Parameters

 

Model Rated voltage Rated current Rated power Doors hole size Door installation
size
Latch stroke Remark
DSN-AMZ AC220V
DC220V
DV110V
100mA
196mA
98mA
<3VA
<50W
<12W
56*70mm diameter φ6
pitch-row 82mm
14mm Use new electromagnet structure, so
three power,voltage is universal.
DSN-AMY
DSN-BMZ
DSN-BMY
DSN-AMZ6 DC6V 400mA < 2.5W Specifically designed to our uninterruptible DC power, used for no secondary power operating supplied place,
which can improve anti-wrong performance.
DSN-AMY6
DSN-BMZ6
DSN-BMY6

Name Electromagnetic lock Series
Indoor Electromagnetic lock  DSN-I/Y(Z)
Inddor Plug and Twist Electromagnetic lock DSN-AMY(Z)
Indoor Handle Electromagnetic lock  DSN-BMY 
Indoor Handle Electromagnetic lock(Open when electricty,Closed when no power) DSN-BMY(Z)
Indoor earthing electromagnetic lock DSN-J/Z(Y)
Indoor Hnadle Electromagnetic lock with voltage display DSN-DMY(Z)
Name Program lock/Aviation socket Series
Program lock for XGN (SF6 fully enclosed switchgear),Two locks and 1 key 202JS
Program lock for XGN (SF6 fully enclosed switchgear),Two locks and 1 key 203JS
Program lock for XGN (SF6 fully enclosed switchgear),Bck door ,Front door 205JS
Program lock for GG-1A(High voltage switchgear),VCB Up disconnecting,Bck door ,Front door 21JS
Program lock  for GG-1A(High voltage switchgear),VCB Up disconnecting,Front door 22JS
Program lock  for GG-1A(High voltage switchgear),VCB Up and down disconnecting,Bck door ,Front door 23JS
Program lock  for GG-1A(High voltage switchgear),VCB Up disconnecting,Front door 24JS
Program lock  for GG-1A(High voltage switchgear),Up disconnecting,Bck door ,Front door 27JS
Program lock  for GG-1A(High voltage switchgear), Disconnecting,Front door 28JS
Aviation socket  JZ-58
Name Outdoor Electromagnetic lock Series
Outdoor Electromagnectic lock  ,AC220 DSW4-Z
Outdoor Electromagnectic lock ,DC220 ,DC110 DSW4-Y

 

Packaging & Shipping

Company Profile

Our Advantages

 

 

 

US $6
/ Piece
|
1 Piece

(Min. Order)

###

After-sales Service: 1 Year
Warranty: 1 Year
Material: Stainless Steel
Certification: CE
Ambient Temperature: -25ºC to +40ºC
Materials: Hard Magnetic Material

###

Samples:
US$ 6/Piece
1 Piece(Min.Order)

|
Request Sample

###

Customization:

###

Model Rated voltage Rated current Rated power Doors hole size Door installation
size
Latch stroke Remark
DSN-AMZ AC220V
DC220V
DV110V
100mA
196mA
98mA
<3VA
<50W
<12W
56*70mm diameter φ6
pitch-row 82mm
14mm Use new electromagnet structure, so
three power,voltage is universal.
DSN-AMY
DSN-BMZ
DSN-BMY
DSN-AMZ6 DC6V 400mA < 2.5W Specifically designed to our uninterruptible DC power, used for no secondary power operating supplied place,
which can improve anti-wrong performance.
DSN-AMY6
DSN-BMZ6
DSN-BMY6

###

Name Electromagnetic lock Series
Indoor Electromagnetic lock  DSN-I/Y(Z)
Inddor Plug and Twist Electromagnetic lock DSN-AMY(Z)
Indoor Handle Electromagnetic lock  DSN-BMY 
Indoor Handle Electromagnetic lock(Open when electricty,Closed when no power) DSN-BMY(Z)
Indoor earthing electromagnetic lock DSN-J/Z(Y)
Indoor Hnadle Electromagnetic lock with voltage display DSN-DMY(Z)
Name Program lock/Aviation socket Series
Program lock for XGN (SF6 fully enclosed switchgear),Two locks and one key 202JS
Program lock for XGN (SF6 fully enclosed switchgear),Two locks and one key 203JS
Program lock for XGN (SF6 fully enclosed switchgear),Bck door ,Front door 205JS
Program lock for GG-1A(High voltage switchgear),VCB Up disconnecting,Bck door ,Front door 21JS
Program lock  for GG-1A(High voltage switchgear),VCB Up disconnecting,Front door 22JS
Program lock  for GG-1A(High voltage switchgear),VCB Up and down disconnecting,Bck door ,Front door 23JS
Program lock  for GG-1A(High voltage switchgear),VCB Up disconnecting,Front door 24JS
Program lock  for GG-1A(High voltage switchgear),Up disconnecting,Bck door ,Front door 27JS
Program lock  for GG-1A(High voltage switchgear), Disconnecting,Front door 28JS
Aviation socket  JZ-58
Name Outdoor Electromagnetic lock Series
Outdoor Electromagnectic lock  ,AC220 DSW4-Z
Outdoor Electromagnectic lock ,DC220 ,DC110 DSW4-Y
US $6
/ Piece
|
1 Piece

(Min. Order)

###

After-sales Service: 1 Year
Warranty: 1 Year
Material: Stainless Steel
Certification: CE
Ambient Temperature: -25ºC to +40ºC
Materials: Hard Magnetic Material

###

Samples:
US$ 6/Piece
1 Piece(Min.Order)

|
Request Sample

###

Customization:

###

Model Rated voltage Rated current Rated power Doors hole size Door installation
size
Latch stroke Remark
DSN-AMZ AC220V
DC220V
DV110V
100mA
196mA
98mA
<3VA
<50W
<12W
56*70mm diameter φ6
pitch-row 82mm
14mm Use new electromagnet structure, so
three power,voltage is universal.
DSN-AMY
DSN-BMZ
DSN-BMY
DSN-AMZ6 DC6V 400mA < 2.5W Specifically designed to our uninterruptible DC power, used for no secondary power operating supplied place,
which can improve anti-wrong performance.
DSN-AMY6
DSN-BMZ6
DSN-BMY6

###

Name Electromagnetic lock Series
Indoor Electromagnetic lock  DSN-I/Y(Z)
Inddor Plug and Twist Electromagnetic lock DSN-AMY(Z)
Indoor Handle Electromagnetic lock  DSN-BMY 
Indoor Handle Electromagnetic lock(Open when electricty,Closed when no power) DSN-BMY(Z)
Indoor earthing electromagnetic lock DSN-J/Z(Y)
Indoor Hnadle Electromagnetic lock with voltage display DSN-DMY(Z)
Name Program lock/Aviation socket Series
Program lock for XGN (SF6 fully enclosed switchgear),Two locks and one key 202JS
Program lock for XGN (SF6 fully enclosed switchgear),Two locks and one key 203JS
Program lock for XGN (SF6 fully enclosed switchgear),Bck door ,Front door 205JS
Program lock for GG-1A(High voltage switchgear),VCB Up disconnecting,Bck door ,Front door 21JS
Program lock  for GG-1A(High voltage switchgear),VCB Up disconnecting,Front door 22JS
Program lock  for GG-1A(High voltage switchgear),VCB Up and down disconnecting,Bck door ,Front door 23JS
Program lock  for GG-1A(High voltage switchgear),VCB Up disconnecting,Front door 24JS
Program lock  for GG-1A(High voltage switchgear),Up disconnecting,Bck door ,Front door 27JS
Program lock  for GG-1A(High voltage switchgear), Disconnecting,Front door 28JS
Aviation socket  JZ-58
Name Outdoor Electromagnetic lock Series
Outdoor Electromagnectic lock  ,AC220 DSW4-Z
Outdoor Electromagnectic lock ,DC220 ,DC110 DSW4-Y

Using a Power Lock

Using a power lock in your vehicle allows you to lock the doors without having to take your hands off the wheel. It is also great for front passengers to use.
locking assembly

Actuator

Among the most common features on any vehicle are power door locks. These locks work by turning a gear mechanism and lock or unlock the door. The gear mechanism is made of an electric motor and spur gears.
Power door lock actuators are critical to the operation of a power door lock feature. When a power door lock actuator fails, it disables the power door lock feature.
The most common complaint about a power door lock actuator is that it locks and unlocks intermittently. This may be due to a problem with the wiring or circuits.
Some symptoms of a faulty power door lock actuator are noises coming from inside the door. For example, when a motor is not turning, it will make a loud “clunk” sound. When a motor is working properly, there will be little or no noise.
A faulty power door lock actuator may also cause a car to lock and unlock randomly. This can happen due to a faulty circuit or circuits wearing out.
Alternatively, a faulty actuator may be the result of a water leak in the door. If this is the case, the water may enter the door lock actuator and cause it to malfunction. Fortunately, there are a number of ways to check the condition of your actuator and fix any problems.
locking assembly

Body controller

Almost all modern day cars have some form of power lock, but only a select few have a body controller to boot. The fancy name is the electronic control unit, but the acronym ECU stands for Electronic Control Unit, or ECU for short. The ECU is responsible for coordinating the myriad electronic components that are dotted throughout your vehicle’s occupant compartment. It also controls things like power windows and the air conditioning. You can see the ECU in action by glancing at your dashboard. It’s a small and power-packed box, but a discerning eye will spot a few stragglers amongst the more mundane tasks. The ECU is also responsible for ensuring the safety of passengers by ensuring that the doors remain unlocked until a specified interval.
The ECU’s lesser known cousins, like the power door lock, are only responsible for a few of the more mundane tasks. Aside from the usual suspects, the ECU also manages the power mirrors and the power windows, albeit on a less than optimal schedule. A faulty ECU isn’t quite as funky as it sounds, and can be rectified by a trip to the local mechanic. If you’re not a mechanic, you’ll likely be able to remedy the situation with a simple door lock replacement.
locking assembly

Check for broken wires

Occasionally, you will need to check for broken wires when using a power lock. Having a broken wire will require you to repair it, or replace it with a new one. However, this process can be quite difficult, as it is hard to reach the motor. If you are unsure what wires are connected to your vehicle, you should consult a wiring diagram. If you do not have a diagram, you can also use a multimeter to check for continuity across all wires. However, a multimeter is not enough to check for broken wires. You will also need rubber gloves to do this safely.
To check for broken wires, first make sure you have access to the wires that are in the lock motor. These are usually located near the plug on the door frame. If you can’t reach them, you can use jumper wires to connect the actuator to the 12 volt power supply and test it for power. If this does not work, you will need to remove the lock motor from its electronic control board and check for a broken wire harness. However, if this is not possible, you can use a Power Probe to apply 12 volts to the actuator.
China Indoor Handle Electromagnetic Lock Open When Electricty, Closed When No Power     power lock dead spaceChina Indoor Handle Electromagnetic Lock Open When Electricty, Closed When No Power     power lock dead space
editor by czh 2022-12-07